| 2012-10-12 16:58:02 | BUILDING PLAN REVIEW |
| | PERMIT: 12100003 |
| | ADD: 5329 GEORGIA AVE |
| | CONT: SCOTT W HEMPHILL |
| | TEL: (561)262-8847 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | OCT.12/2012 |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) THE PLANS ARE SIGNED AND SEALED BY RONNIE DIXON PE |
| | WHY IS THERE A RESIDENTIAL DESIGNER ERVIN KEEL ON A |
| | ENGINEERS LETTERHEAD ADVERTISING ON A COMMERCAIL |
| | PROJECT????? F S 471. |
| | |
| | 2) THIS BUILDING HAS HAD AN EXPLOSION AND EXTREME FIRE |
| | DAMAGE TO THE STRUCTURE, THE SUBMITTED PLANS DO NOT |
| | REFLECT THE CONDITION OF THE BUILDING, WHAT ELEMENTS |
| | ARE DESTROYED, BY FIRE DAMAGE, WHAT ELEMENTS WERE |
| | DESTORYED BY HEAT, AND FAILURE OCCURED. |
| | 2010 EXISTING BUILDING CODE : |
| | 807.4.1 EVALUATION AND ANALYSIS. AN ENGINEERING |
| | EVALUATION AND ANALYSIS THAT ESTABLISHES THE STRUCTURAL |
| | ADEQUACY OF THE ALTERED STRUCTURE SHALL BE PREPARED BY |
| | A REGISTERED ARCHITECT OR ENGINEER AND SUBMITTED TO THE |
| | CODE OFFICIAL. |
| | |
| | 807.4.2 SUBSTANTIAL STRUCTURAL ALTERATION. WHERE MORE |
| | THAN 30 PERCENT OF THE TOTAL FLOOR AND ROOF AREAS OF |
| | THE BUILDING OR STRUCTURE HAVE BEEN OR ARE PROPOSED TO |
| | BE INVOLVED IN STRUCTURAL ALTERATION WITHIN A 12-MONTH |
| | PERIOD, THE EVALUATION AND ANALYSIS SHALL DEMONSTRATE |
| | THAT THE ALTERED BUILDING OR STRUCTURE COMPLIES WITH |
| | THE FLORIDA BUILDING CODE, BUILDING FOR WIND LOADING. |
| | |
| | 3) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 4) FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 |
| | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR |
| | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: |
| | (31)(A) EXTERIOR DOORS. |
| | (B) WINDOWS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| | LOUVERS, EFIS SYSTEMS, |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES |
| | (E) SHUTTERS |
| | (F) SKYLIGHTS |
| | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C |
| | STANDS |
| | |
| | 5) THE WIND DESIGN CRITERIA INDICATES THIS BUILDING AS |
| | A IMPORTANCE FACTOR I OR A SHED TYPE BUILDING, |
| | AGRICULTURAL OUT BUILDING, THE BUILDING CATEGORY IS |
| | CONSIDERED A II WHICH PUTS IT INTO A WINDZONE OF 170 |
| | MPH, 3 SECOND GUST, THIS WILL ALSO EFFECT THE |
| | COMPONENTS AND CLADDING PRESSURES. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |