Plan Review Notes
Plan Review Notes For Permit 12090524
Permit Number 12090524
Review Stop B
Sequence Number 1
Notes
Date Text
2012-09-28 13:53:14BUILDING PLAN REVIEW
 PERMIT: 12090524
 ADD: 1645 PALM BEACH LAKES # 550
 CONT: R LABONTE SEVICES
 TEL: (561)445-2522
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 SEPT. 28/2012
 ACTION: DENIED
  
 1) SHEEET A-1 INDICATES THE WALL SECTION TO BE INFILLED
 WHERE THE OLD LOCATION OF THE DOUBLE DOORS, PLANS LACK
 INFORMATION ON TYPE OF FRAMING AND TYPE OF GYPSUM,
 THICKNESS OF GYPSUM BOARD. 2010 FBC-B 709.1(6) REQUIRE
 A ONE-HOUR FIRE RESISTANCE RATING.
  
 2) PLEASE PROVIDE SIGNAGE OR STENCILING ABOVE RATED
 WALLS WITH WORDING, 2010 FBC-B SECTION: 713.6 FIRE
 WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS
 AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE
 PROTECTED OPENINGS SHALL BE EFFECTIVELY AND PERMANENTLY
 IDENTIFIED WITH SIGNS OR STENCILING IN A MANNER
 ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. SUCH
 IDENTIFICATION SHALL BE ABOVE ANY DECORATIVE CEILING
 AND IN CONCEALED SPACES. SUGGESTED WORDING FOR FIRE AND
 SMOKE BARRIERS: "FIRE AND SMOKE BARRIER ? PROTECT ALL
 OPENINGS.?
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676