| 2012-12-10 11:26:55 | ****CORRECTIONS**** |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | FBC FLORIDA BUILDING CODE 2010 |
| | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL |
| | |
| | COMMENTS FROM PREVIOUS LIST: |
| | |
| | 1. THIS PARCEL IS LOCATED IN SPECIAL HAZARD FLOOD ZONE |
| | A8. WPB MUNICIPAL CODE 94 546(B), ALL NEW IMPROVEMENTS |
| | TO COMPLY WITH REQUIREMENTS FOR NEW CONSTRUCTION. |
| | FINISHED FLOOR SLAB TO BE AT A MINIMUM OF 16.5 FT. THE |
| | GRADING PLAN AND OTHER SHEETS SHOW A BUILDING ELEVATION |
| | OF 20.40 FT. PROPOSED CONSTRUCTION APPEARS TO COMPLY; |
| | PLEASE PROVIDE A SIGNED AND SEALED ELEVATION |
| | CERTIFICATE (CONSTRUCTION DRAWINGS). AN ADDITIONAL |
| | ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO C.O. |
| | (FINAL CONSTRUCTION). THE ELEVATION CERTIFICATE CAN BE |
| | EITHER THE FEMA 2009 ELEVATION CERTIFICATE FORM (OMB |
| | NO. 1660-0008, EXPIRES MARCH 31, 2012) OR ON THE NEW |
| | FORM WHICH WILL BE AVAILABLE NEXT WEEK ON THE FEMA |
| | WEBSITE. THERE WILL BE A ONE YEAR PHASE IN PERIOD |
| | DURING WHICH THE NEW FORM WILL BE VOLUNTARY. |
| | |
| | 2ND REVIEW, PLEASE PROVIDE ELEVATION CERTIFICATE |
| | (CONSTRUCTION DRAWINGS) AS REQUESTED. INFORMATION SUCH |
| | AS PROPOSED ELEVATION, MECHANICAL EQUIPMENT ELEVATION, |
| | AND OTHER ITEMS WILL BE REVIEWED. |
| | |
| | 2. LS 1.0, ARRANGEMENTS OF EXITS, SEE FBC 1015.2.1, |
| | EXIT DOORS TO BE PLACED A DISTANCE APART EQUAL TO NOT |
| | LESS THAN ONE HALF OF THE LENGTH OF THE MAXIMUM OVERALL |
| | DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED |
| | (ONE THIRD DISTANCE IF BUILDING IS SPRINKLERED, SEE |
| | EXCEPTION). |
| | |
| | PLEASE REVISE NOTE (WHICH STATES 1/3 DIAGONAL) AND |
| | DIMENSIONS AS REQUIRED. |
| | |
| | 3. OK. |
| | |
| | 4. LS 1.0, TRAVEL DISTANCE OF 114 FT 4 IN SHOWN FROM |
| | ONE CORNER TO OPPOSITE EXIT. PLEASE ALSO SHOW COMMON |
| | PATH AS IT APPEARS TO EXCEED 75 FEET, FBC 1014.3. |
| | |
| | 2ND REVIEW, PLEASE REVISE TO SHOW COMMON PATH AS |
| | DEFINED BY FBC 1002: |
| | |
| | "THAT PORTION OF EXIT ACCESS WHICH THE OCCUPANTS ARE |
| | REQUIRED TO TRAVERSE BEFORE TWO SEPARATE AND DISTINCT |
| | PATHS OF EGRESS TRAVEL TO TWO EXITS ARE AVAILABLE" (NOT |
| | VISIBLE AS STATED ON PLAN). PLEASE CONTACT ME IF YOU |
| | WISH TO DISCUSS. |
| | |
| | 5. OK |
| | |
| | 6. NOTE THE FOLLOWING REGARDING PRODUCT APPROVALS |
| | FAC9N-3, FBC 1609: |
| | |
| | AC STAND - IF MANUFACTURED ONSITE, PROVIDE A DETAIL. IF |
| | MANUFACTURED OFF SITE, FLORIDA STATE OR LOCAL PRODUCT |
| | APPROVAL REQUIRED |
| | |
| | ALUMINUM IMPACT BI PARTING CAR DOOR SYSTEM - PROVIDE |
| | PRODUCT APPROVAL TO VERIFY DESIGN PRESSURES, IMPACT, |
| | AND METHOD OF INSTALLATION. THIS MAY HAVE BEEN PROVIDED |
| | TO YOU WITH THE RECORDS RESEARCH REQUEST INFORMATION. |
| | |
| | PAIR 4X8 IMPACT STOREFRONT DOOR SYSTEM (DOOR A) - OK |
| | |
| | WINDOW WALL SYSTEM WITH DOOR (DOOR B) - OK |
| | |
| | IMPACT SINGLE DOOR (DOOR C) - OK |
| | |
| | ROOF - ULTRAGARD PVC SR 50 - THE ASSEMBLY SELECTED IS |
| | FOR WOOD DECK, PLAN SHOWS DOUBLE TEES. ENGINEERING |
| | REQUIRED FOR ZONES 2 AND 3 IF ASSEMBLY DESIGN PRESSURE |
| | DOES NOT MEET MINIMUMS SPECIFIED BY ENGINEER. |
| | |
| | NEW EIFS WALL SYSTEM - OK |
| | |
| | BUTT GLAZED WINDOW WALL SYSTEM (PRODUCT APPROVAL OR |
| | TEST REPORT AS PER A 5.0) - OK |
| | |
| | ANY INFORMATION NOT SUBMITTED PRIOR TO PERMIT ISSUANCE |
| | WILL BE REQUIRED TO BE SUBMITTED AS A REVISION. DESIGN |
| | PRESSURES TO MEET REQUIREMENTS ON S 7.1. |
| | |
| | 7. OK. |
| | |
| | 8. PLEASE PROVIDE THE ENERGY CALCS. THE DOCUMENT WHICH |
| | WAS UPLOADED WHICH IS NAMED LOADENERGYCALCULATIONS.PDF |
| | IS THE SAME DOCUMENT AS THE CIVIL COST ESTIMATE. SEE |
| | FBC 2010 ENERGY 103.2.3. |
| | |
| | 9. OK. |
| | |
| | 10. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY |
| | REQUIRED. PLEASE CONTACT 561-233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | |
| | |