| Plan Review Notes For Permit 12090097 |
| Permit Number |
12090097 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-09-11 16:11:00 | FBC 2010 EXISTING BUILDING CODE | | | FBC 2010 ACCESSIBILITY CODE | | | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | 1. SHEET A-2 - THE MENS AND WOMENS RESTROOMS APPEAR NOT | | | TO MEET THE 2010 ACCESSIBILTY CODE. PLEASE SEE SECTION | | | 604.3.2 FOR WATER CLOSET CLEARANCE (THE STALLS WOULD BE | | | REQUIRED TO BE A MINIMUM OF 7'-1" WIDE TO ACHIEVE THE | | | REQUIRED 5' CLEAR SPACE FOR THE WATER CLOSET), SECTION | | | 202.4.1 FOR DISPROPORTIONATE COST, AND SECTION 202.4.2 | | | FOR ACCESSIBLE FEATURES IN THE EVENT OF | | | DISPROPORTIONALITY. | | | | | | ***NOTES*** | | | 1. PLUMBING DRAWINGS ARE OK | | | | | | 2. FUEL GAS IS NOT INCLUDED IN THIS REVIEW. SEPARATE | | | APPLICATION, PLAN, REVIEW, FEES, AND PERMIT REQUIRED. | | | | | | 3. SHEET C-1: THE FBC CODE EDITION FOR THIS PROJECT IS | | | FBC 2010 | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|