Plan Review Notes
Plan Review Notes For Permit 12080534
Permit Number 12080534
Review Stop M
Sequence Number 1
Notes
Date Text
2012-08-21 09:04:222010 FBC
  
 DENIED BY MECHANICAL
  
 1) SUBMIT TWO SETS OF ENERGY CALCULATIONS AND EQUIPMENT
 SIZING CALCULATIONS.FBC ENERGY CONSERVATION CHAPTER 4
 AND FBCR M1401.3
  
 2) THE TRANSFER DUCTS FOR NEW BEDROOM #2 AND THE NEW
 MASTER BEDROOM ARE NOT CORRECT. THE PLAN SHOWS THE
 RETURN DUCTS TIED BETWEEN THE TWO ROOMS. IN ORDER TO BE
 CODE COMPLIANT, THEY NEED TO TRANSFER THE AIR FROM EACH
 ROOM TO THE COMMON HALL OR BE TIED DIRECTLY INTO THE
 RETURN AIR AS REQUIRED BY FBCR M1602.4.
  
 3) SPECIFY THE EQUIPMENT, THE SEER AND THE LOADS IN THE
 EQUIPMENT SCHEDULE ON SHEET 5.1. FBC M1401.3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]