| 2012-09-04 09:50:51 | BUILDING PLAN REVIEW |
| | PERMIT: 12080493 |
| | ADD: 255 WALTON |
| | CONT: ANCHOR GENERAL CONTRACTING |
| | TEL: (561)386-1266 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) DISCREPANCY BETWEEN THE DESCRIPTION OF WORK INCLUDED |
| | WITH IN THE PLANS, SECTIONS SCRATCHED OUT IN PEN ON THE |
| | PLANS AND THE WRITTEN PERMIT APPLICATION UNDER THE |
| | HEADING WORK DESCPRIPTION. PLEASE CORRELATE ALL THE |
| | WORK TO BE COVERED UNDER THIS PERMIT. 2010 FBC-B |
| | ADMINISTRATIVE SECTION 107.2.1.3 ADDITIONAL INFORMATION |
| | REQUIRED. |
| | |
| | 2) NEITHER THE A-1 OR E-1 INDICATE COMPLIANCE WITH 2010 |
| | FBC-B 916.1.1, CARBON MONOXIDE ALARMS, 916.1.2 |
| | COMBINATION ALARMS OR 907.2.11.2.SMOKE ALARMS IN R-2 |
| | RESIDENCIES. |
| | |
| | 3) PLEASE NOTE THAT ROOM NUMBER 3 & 5 DO NOT MEET THE |
| | ROOM SIZE REQUIREMENTS FOR AN EFFICIENCY DWELLING UNIT. |
| | 2010 FBC-B 1208.4 EFFICIENCY DWELLING UNITS. |
| | AN EFFICIENCY LIVING UNIT SHALL CONFORM TO THE |
| | REQUIREMENTS OF THE CODE EXCEPT AS MODIFIED HEREIN: |
| | |
| | 1. THE UNIT SHALL HAVE A LIVING ROOM OF NOT LESS THAN |
| | 220 SQUARE FEET (20.4 M2) OF FLOOR AREA. AN ADDITIONAL |
| | 100 SQUARE FEET (9.3 M2) OF FLOOR AREA SHALL BE |
| | PROVIDED FOR EACH OCCUPANT OF SUCH UNIT IN EXCESS OF |
| | TWO. |
| | 2. THE UNIT SHALL BE PROVIDED WITH A SEPARATE CLOSET. |
| | 3. THE UNIT SHALL BE PROVIDED WITH A KITCHEN SINK, |
| | COOKING APPLIANCE AND REFRIGERATION FACILITIES, EACH |
| | HAVING A CLEAR WORKING SPACE OF NOT LESS THAN 30 INCHES |
| | (762 MM) IN FRONT. LIGHT AND VENTILATION CONFORMING TO |
| | THIS CODE SHALL BE PROVIDED. |
| | 4. THE UNIT SHALL BE PROVIDED WITH A SEPARATE BATHROOM |
| | CONTAINING A WATER CLOSET, LAVATORY AND BATHTUB OR |
| | SHOWER. |
| | |
| | WEST PALM BEACH MUNICIPLE CODE SEC. 18-109. - CONFLICT |
| | WITH OTHER CODES. |
| | |
| | IN ANY CASE WHERE A PROVISION OF ANY ZONING, BUILDING, |
| | ELECTRICAL, PLUMBING, HEALTH, FIRE, OR SAFETY CODE OF |
| | THE CITY IS IN CONFLICT, THE PROVISION WHICH |
| | ESTABLISHES THE HIGHER STANDARD FOR THE PROMOTION AND |
| | PROTECTION OF THE PUBLIC HEALTH AND SAFETY SHALL |
| | PREVAIL. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |