| Plan Review Notes For Permit 12080396 |
| Permit Number |
12080396 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-08-13 12:16:26 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. CITY OF WEST PALM BEACH IS IN THE 170MPH V(ULT) WIND | | | ZONE, NOT 140MPH, FBC R 301.1.. | | | | | | YOU MAY USE THE DESIGN PRESSURE CHART FROM THE 2007 | | | RESIDENTIAL CODE, 140MPH, AS IT EXCEEDS THE | | | REQUIREMENTS (170MPH V(ULT) = 132MPH V(ASD), FBC | | | RESIDENTIAL TABLE 301.2.1.3. | | | | | | WORST CASE FOR THIS JOB ARE -54.1PSF ZONE 5, -43.8PSF | | | ZONE 4. | | | | | | PLEASE REVISE INSTALLATION SCHEDULE; -40PSF TOO LOW FOR | | | THIS JOB. | | | |
|