| Plan Review Notes For Permit 12080363 |
| Permit Number |
12080363 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-09-19 14:35:50 | BUILDING PLAN REVIEW | | | PERMIT: 12080363 | | | ADD: 6651 N JOG RD | | | CONT: PRECON CORP. | | | TEL: ? | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) 107.3.5 8 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS | | | MISSING STRUCTURAL DESIGN OF THE FOUNDATION, SOILS | | | REPORT TO CONFIRM WHAT THE SAFE MINIMUM BEARING VALUE | | | SHOULD BE OF THE SUPPORTING SOILS. | | | | | | 2) 107.3.5 8 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS | | | MISSING WIND DESIGN. | | | | | | 3) HANDRAIL NOTE # 1 INDICATES THE HANDRAILS ARE TO | | | MEEET THE REQUIEMENTS OF THE S.F.B.C., WE ARE CURRENTLY | | | UNDER THE 2010 FBC 1013.3 & 1013.5. | | | | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|