| Notes |
| Date |
Text |
| 2012-10-05 10:48:33 | FBC ACCESSIBILITY 2010 | | | FBC PLUMBING 2010 REVIEW #2 | | | DENIED: | | | | | | 1. SHEETS A-1 AND A-8 (1) PARTIALLY COMPLIED: | | | FBC ACCESSIBILITY CODE 2010 604.2 LOCATION. THE WATER | | | CLOSET SHALL BE POSITIONED WITH A WALL OR PARTITION TO | | | THE REAR AND TO ONE SIDE. THE CENTERLINE OF THE WATER | | | CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM TO 18 INCHES | | | (455 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION. | | | | | | 2. ***PROVISO*** | | | IF A SINGLE DRINKING FOUNTAIN IS TO BE USED IT MUST | | | COMPLY WITH 602.1 THROUGH 602.6 AND 602.7. A CUP HOLDER | | | DOES NOT COMPLY WITH 211.2 | | | | | | FBC ACCESSIBILITY CODE 2010 211.2 MINIMUM NUMBER. NO | | | FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. | | | ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH | | | 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH | | | 602.7. | | | EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES | | | WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE | | | PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING | | | FOUNTAINS. | | | | | | 3. | | | | | | 4. | | | | | | ***NOTE*** | | | IRRIGATION IS NOT PART OF THIS REVIEW. SEPARATE | | | APPLICATION, DRAWING, REVIEW, AND FEE REQUIRED. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 |
|