| 2012-08-13 11:39:54 | BUILDING PLAN REVIEW |
| | PERMIT: 12071067 |
| | ADD: 1950 N CONGRESS # 409 |
| | CONT: CILAS CONCRETE |
| | TEL: (561)255-3725 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) DISCREPANCIES SHEET A-1 WIND INFORMATION IS |
| | INDICATED TO BE DESIGNED TO THE 2010 FBC-B BUT THE |
| | BASIC WIND SPEED IS INDICATED AS 140 MPH, 3 SECOND |
| | GUST. |
| | PLEASE SEE 2010 FBC-B FIGURE 1609A FOR CATEGORY LL |
| | BUILDINGS. |
| | |
| | 2) DISCREPANCIES SHEET A-1 WIND INFORMATION IS |
| | INDICATING THIS BUILDING AS A SINGLE FAMILY HOME, IT |
| | APPEARS THE UNIT NUMBER BEING 409 THIS IS A R-2 |
| | RESIDENCE LOCATED ON THE 4TH FLOOR. ADDITIONAL |
| | INFORMATION REQUIRED. 107.2.13 ALSO IF THIS UNIT IS |
| | LOCATED ON THE FOURTH FLOOR THERE SHOULD BE A |
| | ADJUSTMENT FACTOR FOR HEIGTH. A HEIGHT AND EXPOSURE |
| | ADJUSTMENT COEFFICIENT, * SHALL BE DETERMINED FROM 2010 |
| | FBC-B TABLE 1609.7.2. ASCE 7-10. |
| | |
| | 3) DISCREPANCY SHEET A-1 WINDOW TABLE OF POSTIVE & |
| | NEGATIVE WINDOW PRESURES IS FOR LAWSON WINDOWS WHEREAS |
| | PRODUCT APPROVALS SUBMITTED ARE PGT. PRODUCT APPROVALS |
| | SUBMITTED NOT PER PLAN. DISCREPANCY. 107.2.1.3. |
| | |
| | 3) SHEET A-2 PRESSURES FOR SHEET A-2 ARE INDICATED AS |
| | FOR A BUILDING WITH A MEAN ROOF HEIGTH OF 15 FT. , IT |
| | IS NOT CERTAIN WITH THE LISTED ABOVE DISCREPANCIES IF |
| | THESE PRESSURES ARE V(ULT) OR V(ASD) SEE 2010 FBC-B |
| | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- |
| | CHAPTER 6 OF ASCE 7-10. |
| | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C |
| | 1609.3 WIND SPEED CONVERSION |
| | 1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 |
| | |
| | 2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. |
| | |
| | 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.4 & ASCE 7-10 |
| | |
| | 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. |
| | |
| | 5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE |
| | TABLE 1609.2(2) . |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |