| Plan Review Notes For Permit 12070677 |
| Permit Number |
12070677 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-07-19 14:40:53 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- ENGINEER TO PROVIDE ACTUAL RAS 117 CALCULATIONS AS | | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | | SUBMITTED. SEC. 107.2.1.3 CITY AMENDMENTS TO FBC. | | | | | | 2- ENGINEER TO REVISE NAILING SPACING: | | | A) THE MINIMUM FASTENER SPACING SHALL NOT BE LESS THAN | | | 4" O.C. SEE RAS 117 SEC. 8.1 AND REVISE AS REQUIRED. | | | | | | B) ALL FRACTIONS SHALL BE ROUNDED DOWN TO THE NEXT | | | WHOLE NUMBER. SEE RAS 117 SEC. 10.4.5 AND REVISE AS | | | REQUIRED. | | | | | | C) ENGINEER TO SPECIFY THE NAIL SPACING AT THE BASE | | | SHEET LAP. MISSING THE INFORMATION. SEC. 107.2.1 CITY | | | AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|