2012-07-27 11:18:11RESIDENTIAL (R3) RE-ROOF, SECOND BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 NOTE:
 ITEMS REQUESTED ON FIRST CHECKLIST WERE NOT PROPERLY
 ADDRESSED. ENGINEERING SUBMITTED WAS FOR THE ROOF TILE
 INSTALLATION. THIS WAS NOT REQUESTED. SEE BELOW FOR THE
 REQUESTED ITEMS:
  
 1- ACCORDING TO HOUSE RECORDS EXISTING HOUSE WAS BUILT
 WITH SHINGLES AS THE ROOF COVER SHINGLES NOT CONCRETE
 TILE. PROVIDE ENGINEERING SHOWING THAT STRUCTURE WILL
 SUPPORT THE CONCRETE TILE ADDITIONAL LOAD. SEC.
 107.2.1.3 CITY AMENDMENTS TO FBC. PROVIDE 2 COPIES WITH
 ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY
 CHAPTER 471 FLORIDA STATUTE.
  
 2- FLAT ROOF:
 A) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS AS
 REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA
 09-0224.01 SUBMITTED. NEED THE CALCULATIONS TO MEET THE
 DESIGN PRESSURES AS REQUIRED BY SEC. R301.2.1.4.3 OF
 2010 FBC-RESIDENTIAL.
  