| Plan Review Notes For Permit 12070514 |
| Permit Number |
12070514 |
|
| Review Stop |
FIRE |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-07-19 14:05:19 | 901 SOUTH OLIVE AVENUE | | | PERMIT #12070514 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIRS AND | | | PLATFORM ELEVATION CHANGE. HANDRAILS SHALL BE LOCATED | | | NOT LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES | | | ABOVE THE SURFACE OF THE TREAD, MEASURED VERTICALLY TO | | | THE TOP OF THE RAIL FROM THE LEADING EDGE OF THE TREAD. | | | HANDRAIL ENDS SHALL BE RETURNED TO THE WALL OR FLOOR OR | | | SHALL TERMINATE AT NEWEL POSTS. HANDRAIL CROSS SECTION | | | SHALL HAVE A DIAMETER OF NOT LESS THAN 1.25 INCHES AND | | | NOT MORE THAN 2 INCHES. | | | | | | STEPS SHALL HAVE A TREAD DEPTH OF AT LEAST 13-INCHES. | | | PROVIDE A CONTRASTING STRIPE ON EACH STEPPING SURFACE | | | OF THE LEADING EDGE OR TREAD NOSING TO MAKE THE | | | PRESENCE OF AN ELEVATION CHANGE READILY APPARENT TO | | | OCCUPANTS. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|