| Plan Review Notes For Permit 12070351 |
| Permit Number |
12070351 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2012-07-24 10:14:13 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. AN EDGE DISTANCE OF 2.25" REQUIRES A FACTOR OF .5 | | | APPLIED TO THE ANCHOR SPACING, SEE CHART ON SHEET 10. | | | | | | 2. CONNECTION TYPE PROPOSED NOT CLEAR. PLEASE REVISE TO | | | CORRESPOND WITH ANCHOR CHARTS; FOR INSTANCE, "9 TOP." | | | FOR INSTANCE, WALL MOUNT 9 WAS CIRCLED, THIS ANCHOR | | | SPACING CIRCLED (9 TOP AND 9 BOTTOM), BUT THIS COLUMN | | | STATES 1/2, BUT ONLY ONE DETAIL CIRCLED, APPEARS THAT | | | TWO DIFFERENT CONNECTION TYPES ARE PROPOSED (USE OF | | | 1/2), NOT CLEAR WHICH ONE IS PROPOSED. | | | | | | |
|