| Plan Review Notes For Permit 12060693 |
| Permit Number |
12060693 |
|
| Review Stop |
FIRE |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-06-30 20:58:04 | 1201 ALLENDALE ROAD | | | PERMIT #12060693 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | DESIGN SHALL CONFORM TO THE 2010 EDITION OF THE FLORIDA | | | FIRE PREVENTION CODE WHICH CONTAINS THE 2009 EDITION OF | | | BOTH NFPA 1 AND NFPA 101 WITH FLORIDA AMENDMENTS. | | | | | | PROVIDE A LIFE SAFETY PLAN INDICATING OCCUPANCY TYPE(S) | | | AND SHOWING ALL EXIT DOORS, EXIT SIGNS, EMERGENCY LIGHT | | | FIXTURES, TRAVEL DISTANCES AND FIRE EXTINGUISHERS. | | | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | | | HANDRAILS SHALL BE CONTINUOUSLY GRASPABLE ALONG THEIR | | | ENTIRE LENGTH AND HAVE A CROSS SECTION DIAMETER OF NOT | | | LESS THAN 1.25 INCHES AND NOT MORE THAN 2 INCHES. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | |
|