| Plan Review Notes For Permit 12060465 |
| Permit Number |
12060465 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-06-29 18:10:35 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | 2. THIS PARCEL APPEARS TO BE LOCATED IN EXPOSURE D, FBC | | | RESIDENTIAL 301.2.1.4.3. WORST CASE PRESSURES FOR A 15' | | | MRH, 10SF, ZONE 5 ARE +46 / -61.6. PRESSURES PROPOSED | | | ARE TOO LOW FOR EXPOSURE D. | | | | | | 3. REVISE PLAN TO SHOW EMERGENCY MEANS OF ESCAPE, FBC | | | RESIDENTIAL 310.4. | | | |
|