| 2012-07-03 15:48:02 | BUILDING PLAN REVIEW |
| | PERMIT: 12060310 |
| | ADD: 428 10TH STREET |
| | CONT: RECORD CONSTRUCTION |
| | TEL: (561)662-2775 |
| | 2010 FLORIDA BUILDING CODE/ RESIDENTIAL W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) 2010 FBC-R 3012.1.2PROTECTION OF OPENINGS, THE |
| | CONTRACTOR SUBMITTED PRODUCT APPROVALS FOR EXTERIOR |
| | DOORS AND MULLIONS BUT NO WINDOW APPROVALS |
| | WERE SUBMITTED WTIHIN THIS PERMIT PACKAGE. |
| | |
| | 2) 2010 WPB ADMINISTRATIVE CODE 107.3.4.1 DESIGN |
| | PROFESSIONALS SHALL REVIEW PRODUCT APPROVALS WHICH ARE |
| | REGULATED BY DCA RULE 9N-3 , SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 3) 2010 FBC-R R807.1 ATTIC ACCESS. BUILDINGS WITH |
| | COMBUSTIBLE CEILING OR ROOF CONSTRUCTION SHALL HAVE AN |
| | ATTIC ACCESS OPENING TO ATTIC AREAS THAT EXCEED 30 |
| | SQUARE FEET (2.8 M2) AND HAVE A VERTICAL HEIGHT OF 30 |
| | INCHES (762 MM) OR MORE. |
| | |
| | THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 |
| | INCHES BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE |
| | LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE |
| | LOCATION. A 30-INCH (762 MM) MINIMUM UNOBSTRUCTED |
| | HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME |
| | POINT ABOVE THE ACCESS OPENING. SEE SECTION M1305.1.3 |
| | FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS |
| | LOCATED IN ATTICS. |
| | |