| Plan Review Notes For Permit 12060220 |
| Permit Number |
12060220 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-07-14 10:47:27 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. AS THE RENOVATION COST IS OVER 30% OF THE VALUE OF | | | THE STRUCTURE (PER PAPA), PLEASE SEE FBC 2010 ENERGY | | | CONSERVATION, TABLE 101.4.1, BUILDING ENVELOPE | | | COMPONENTS ARE TO COMPLY WITH SECTION 502, FBC ENERGY | | | CONSERVATION. IF AN APPRAISAL WITH A DIFFERENT VALUE IS | | | AVAILABLE, PLEASE PROVIDE. | | | | | | 2. FBC 1403.7, CLEARANCE BETWEEN EXTERIOR WALL | | | COVERINGS AND FINAL EARTH GRADE SHALL NOT BE LESS THAN | | | 6". REVISE DETAIL TO SHOW COMPLIANCE. | | | | | | |
|