| Plan Review Notes For Permit 12060134 |
| Permit Number |
12060134 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-07-05 15:07:45 | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | FBC PLUMBING 403.1 | | | TYPE D OCCUPANCY REQUIRES A SERVICE SINK (A LAUNDRY TUB | | | WOULD BE OK) AND DRINKING FOUNTAIN FOR OVER 15 | | | OCCUPANTS. | | | | | | FBC ACCESSIBILITY 211.2 | | | 211.2 MINIMUM NUMBER. NO FEWER THAN TWO DRINKING | | | FOUNTAINS SHALL BE PROVIDED. ONE DRINKING FOUNTAIN | | | SHALL COMPLY WITH 602.1 THROUGH 602.6 AND ONE DRINKING | | | FOUNTAIN SHALL COMPLY WITH 602.7. | | | EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES | | | WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE | | | PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING | | | FOUNTAINS. | | | |
|