| Notes |
| Date |
Text |
| 2012-07-27 13:03:52 | BUILDING PROVISO: | | | SHEET A-2 NOTE 20 INDICATES A NEW SHOWER CEILING M.R. | | | G.W.B. THE PLANS DO NOT INDICATE THE THICKNESS OF THE | | | MOISTURE RESISTANT BYPSUM WALL BOARD NOR DO THEY | | | INDICATE THE FRAMING SPACING. 2509.3. ON CEILINGS WHERE | | | FRAME SPACING EXCEEDS 12 INCHES (305 MM) O.C. FOR | | | 1/2-INCH-THICK (12.7 MM) WATER-RESISTANT GYPSUM BACKING | | | BOARD AND MORE THAN 16 INCHES (406 MM) O.C. FOR | | | 5/8-INCH-THICK (15.9 MM) WATER-RESISTANT GYPSUM BACKING | | | BOARD. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|