Plan Review Notes
Plan Review Notes For Permit 12050519
Permit Number 12050519
Review Stop B
Sequence Number 2
Notes
Date Text
2012-08-24 12:07:29BUILDING PLAN REVIEW
 PERMIT: 12050519
 ADD: 4847 FRED GLADSTONE DR
 CONT: THE WHITING TURNER CO.
 TEL: (954)776-0800/ HENRY SHAWAH
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 1) COMPLIED.
  
 2) 2ND REQUEST, 2A) THE PRODUCT APPROVALS SUBMITTED,
 NONE OF THE PRODUCT APPROVALS PROVIDED THE TECHNICAL
 SHEETS, AND CAN NOT BE EVALUATED FOR CODE COMPLIANCE
 FOR WIND, COMPONENTS AND CLADDING AND PROTECTION OF
 OPENINGS PER 2010 FBC-B 106.3.3, 1609.1.2(1).
  
 2B) THE PRODUCT APPROVALS SUBMITTED 2 INDICATE THEY ARE
 NON-IMPACT RATED, IT CAN NOT BE DETERMINED FROM THE
 PLANS IF THESE WINDOWS AND DOORS ARE INTERIOR GLAZING
 UNITS OR IF THE DESIGNER IS PLANNING TO USE NOA
 08-0528.01 SLIDING DOOR W/ BREAK-A-WAY & NOA 08-0715.14
 YKK STOREFRONT NON-IMPACT RATED AS EXTERIOR GLAZING
 UNITS. SEE 2010 FBC-B 1609.1.2(1) PROTECTION OF WINDOWS
 FOR OPENINGS FROM GRADE TO THE 30'-0" ELEVATION. IF
 STORM SHUTTERS ARE TO BE IMPLEMENTED PLEASE REVIEW :
  
 PLEASE NOTE: 104.6*/ 1609.1.4/ 1714.5 STANDARDS FOR
 WIND-BORNE DEBRIS IMPACT PROTECTION QUESTION# 13
 RECOGNIZING SUCH CONCERNS AS ABSENTEE OWNERS, OR CASES
 WHERE LONGER TIME & EFFORT IS NECESSARY TO SECURE
 SHUTTERS ON LARGE OR MULTI-STORY BUILDINGS, WHAT
 MEASURES ARE BEING RECOMMENDED OR IMPLEMENTED TO ENSURE
 THAT COMPLETE INSTALLATION OR SECURING IS DONE
 SUFFICIENTLY IN ADVANCE OF THE HURRICANE?
  
 IN MATTERS CONCERNING PUBLIC SAFETY, HEALTH, AND THE
 GENERAL WELFARE NOT SPECIFICALLY ADDRESSED IN THE CODE,
 SECTION 104.6 OF THE FLORIDA BUILDING CODE, BUILDING,
 CHAPTER 1,
 ADMINISTRATIVE CODE2004 EDITION AS AMENDED BY THE CITY
 OF WEST PALM BEACH, PROVIDES THE ABILITY FOR THE
 BUILDING OFFICIAL TO IMPLEMENT REQUIREMENTS FOR
 ENSURING STABILITY, STRENGTH, AND THE PROPER OPERATION
 OF EXISTING BUILDINGS.
  
 IN ORDER TO ASSURE THE SECURING OF SHUTTERS ON LARGE OR
 MULTI-STORY BUILDINGS, OR MULTIPLE
 ON THE SAME PROPERTY, PRE-STORM PREPARATION PLANS MUST
 BE SUBMITTED BY THE PROPERTY OWNERS OR MANAGING AGENTS
 FOR REVIEW BY THE CONSTRUCTION SERVICES DEPARTMENT. ANY
 SUCH PLAN SHALL INCLUDE, AT A MINIMUM, ON SITE LOCATION
 OF THE SHUTTERS, PARTY RESPONSIBLE FOR SECURING THE
 SHUTTERS ( SAID PARTY MUST BE LOCATED WITHIN PALM BEACH
 COUNTY), TOTAL NUMBER OF OPENINGS TO BE PROTECTED AND
 THE TOTAL TIME REQUIRED TO SECURE ALL OPENINGS.
 PROTECTION OF OPENINGS SHALL BE ACCOMPLISHED WITHIN
 TWELVE (12) HOURS OR LESS OF THE
 OFFICIAL NOTIFICATION BY THE NATIONAL WEATHER SERVICES
 OF A HURRICANE WATCH.
  
 PROVISIONS IN THE BUILDING CODES (AND THIS STANDARD)
 ARE NOT INTENDED TO PROHIBIT THE USE OF ALTERNATE
 MATERIALS AND METHODS, AND THE BUILDING OFFICIAL TO
 REVIEW AND APPROVE ANY ALTERNATE DEEMED EQUIVALENT IN
 QUALITY, STRENGTH, EFFECTIVENESS, FIRE RESISTANCE,
 DURABILITY AND SAFETY PRESCRIBED BY THIS CODE. BASED
 UPON THIS CODE PROVISION, ACCEPTANCE OF ALTERNATE
 MATERIALS AND METHODS MAY BE APPROVED ON A CASE-BY-CASE
 BASIS AND SHALL REQUIRE SUFFICIENT EVIDENCE OR PROOF TO
 SUBSTANTIATE ANY CLAIM MADE REGARDING THE ALTERNATE.
  
 IN LEA OF LARGE MISSILE IMPACT RATED WINDOWS, STORM
 SHUTTERS MAY BE USED ON THE FIRST FLOOR IF: 104.6*/
 1609.1.4/ 1714.5 STANDARDS FOR WIND-BORNE DEBRIS IMPACT
 PROTECTION.
  
 2C) IF STORM SHUTTERS ARE GOING TO BE INSTALLED PLEASE
 COMPLY WITH:PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC
 ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT
 GLAZING. FBC 1609.1.4.
  
 FL BLD CODE 2004 SECTION 106.3.3,
 1609.1.4, 1714.5.1 & EXIST BUILD CODE 507.3.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION SCHEDULE
 SUMMARIZING & IDENTIFYING OPENING SIZES, STORY HEIGHTS,
 UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM BAR
 REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT
 TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT
 APPLICATION TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 COMMENT FROM 1ST REVIEW. SHEET R-A621 INDICATES THE
 WINDOW SIZES BUT NO PRODUCT APPROVALS WERE SUBMITTED
 INDICATING COMPLIANCE WITH THE 2010 EXISTING BUILDING
 CODE SECTION 606.4 REPLACEMENT OF WINDOWS. REPLACEMENT
 OF WINDOWS AND DOORS. THE REPLACEMENT OF GARAGE DOORS,
 EXTERIOR DOORS, SKYLIGHTS, OPERATIVE AND INOPERATIVE
 WINDOWS SHALL BE DESIGNED AND CONSTRUCTED TO COMPLY
 WITH CHAPTER 16 OF THE FLORIDA BUILDING CODE, BUILDING
 . 1609.1.2 PROTECTION OF OPENINGS &1609. 6.4.4.1
 COMPONENTS & CLADDING,
  
 2010 FBC 107.3.4.1* THOSE PRODUCTS THAT ARE REGULATED
 BY DCA RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD PRIOR TO THE
 SUBMITTAL FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015
 (2) THE ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND
 REVIEWING ALL PROJECT DATA, REPORTS, SHOP DRAWINGS
 ETC..
  
 3) 2010 FBC-B 1609.6.4.4.1 COMPONENTS & CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)
 (B) WINDOWS
 (E) SHUTTERS
 (G) PRE-ENGINEERED A/C STANDS
  
 4) SEMI-COMPLIED.
  
 5) COMPLIED.
  
 6) COMPLIED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  