2012-06-08 15:36:49BUILDING REVIEW 2ND REVIEW.
 2010 FBC.
  
 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 101.4.3 AND 401 OF 2010 FBC-ENERGY CONSERVATION.
  
 2-WALL SECTION ON SHEET #2:
 A) REVISED CLOSET WALL SECTION SPECIFIES R-19 ROOF
 INSULATION. R-19 INSULATION DOESN'T FIT ON THE 2X6
 RAFTERS. REVISE AS REQUIRED. COORDINATE R-VALUE WITH
 THE ONE REQUIRED ON THE ENERGY CALCULATIONS.
 ***NOTE: ENERGY CALCULATIONS REQUIRE R-30 MIN. FOR
 CEILING INSULATION. SEE TABLE 402.1.1 OF 2010
 FBC-ENERGY CONSERVATION.
  