| Plan Review Notes For Permit 12040671 |
| Permit Number |
12040671 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-04-26 12:45:40 | BUILDING PROVISO: | | | 2010 FBC-B 1507.2.8 UNDERLAYMENT APPLICATION. FOR ROOF | | | SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL | | | (17-PERCENT SLOPE) AND UP TO FOUR UNITS VERTICAL IN 12 | | | UNITS HORIZONTAL (33-PERCENT SLOPE), UNDERLAYMENT SHALL | | | BE TWO LAYERS APPLIED IN THE FOLLOWING MANNER. APPLY A | | | MINIMUM 19-INCH-WIDE (483 MM) STRIP OF UNDERLAYMENT | | | FELT PARALLEL WITH AND STARTING AT THE EAVES, FASTENED | | | SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, | | | APPLY 36-INCH-WIDE (914 MM) SHEETS OF UNDERLAYMENT | | | OVERLAPPING SUCCESSIVE SHEETS 19 INCHES (483 MM), BY | | | FASTENED SUFFICIENTLY TO HOLD IN PLACE. DISTORTIONS IN | | | THE UNDERLAYMENT SHALL NOT INTERFERE WITH THE ABILITY | | | OF THE SHINGLES TO SEAL. FOR ROOF SLOPES OF FOUR UNITS | | | VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE) OR | | | GREATER, UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE | | | FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED SHINGLE | | | FASHION, PARALLEL TO AND STARTING FROM THE EAVE AND | | | LAPPED 2 INCHES (51 MM), FASTENED SUFFICIENTLY TO HOLD | | | IN PLACE. DISTORTIONS IN THE UNDERLAYMENT SHALL NOT | | | INTERFERE WITH THE ABILITY OF THE SHINGLES TO SEAL. | | | |
|