| Plan Review Notes For Permit 12040652 |
| Permit Number |
12040652 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-04-30 15:06:44 | BUILDING PLAN REVIEW | | | PERMIT:12040652 | | | ADD: 7422 S DIXIE HWY | | | CONT: LANTANA CONSTRUCTION | | | TEL: (561)312-3600 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET 1 PLEASE SEE NEW 2010 ACCESSIBILITY CODE AND | | | FIGURE 604.8.1.6 WHEELCHAIR ACCESSIBLE TOILET | | | COMPARTMENT IN NEW CONSTRUCTION. THE MINIMUM DIMENSIONS | | | ARE 84 1/2 " X 60" WITH THE WATERCLOSET AND LAV LOCATED | | | ON THE 84 1/2" WALL. THE LAV CAN NOT OVER LAP INTO THE | | | CLEAR FLOOR SPACE FOR THE WATER CLOSET.SEE FIGURE | | | 604.3.1. | | | | | | 2) NEW TO THE 2010 ACCESSIBILITY CODE GRAB BARS ARE NO | | | LONGER MEASURED TO THE CENTER LINE BUT TO THE TOP OF | | | THE BAR PER SECTION 604.8.1.5/ 609.4 THE TOP OF THE | | | GRIPPING SURFACE 33 INCHES MINIMUM AND 36 INCHES | | | MAXIMUM. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|