| Date |
Text |
| 2012-04-24 09:06:38 | BUILDING PLAN REVIEW |
| | PERMIT: 12040528 |
| | ADD: 5335 N MILITARY TRAIL SUITE # 32 |
| | CONT: MIKE MOORE CONSTRUCTION |
| | TEL: (561)301-9468 |
| | |
| | 2010 FLORIDA BUILDING CODE W/ |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) SHEET A-1 THE LOCATION FOR THE DRINKING FOUNTAIN |
| | INDICATES A SIDE APPROACH WITH THE DOOR ENCROACHING |
| | INTO THE CLEAR FLOOR SPACE REQUIRED FOR THE DRINKING |
| | FOUNTAIN. PLEASE REVIEW SECTION 2010 FBC-B 11-602.2 THE |
| | REQUIRED FLOOR SPACE FOR DRINKING FOUNTAINS REQUIRES A |
| | FORWARD APPROACH CENTERED ON THE UNIT. |
| | |
| | 2) SHEET A-2 DETAIL # 2 PLEASE REVIEW SPOUT HEIGHTS: |
| | 2010 FBC-B 11-602.4 36 INCHES ABOVE FLOOR |
| | 2010 FBC-B 11-602.7 SPOUT HEIGHTS FOR STANDING PEOPLE |
| | |
| | 3) SHEET A-2 DETAIL # 3. PLEASE BE AWARE OF A 2010 |
| | FBC-B CODE CHANGE, FOR THE HEIGHT OF GRAB BARS, THE |
| | PLAN INDICATES CENTER LINE OF GRAB BARS 33"-36", 2010 |
| | FBC-B 11-609.4 POSITION OF GRAB BARS IS NOW MEASURED |
| | FROM THE FINISH FLOOR TO THE TOP OF THE GRIPPING |
| | SURFACE 33"-36 " IN THE HORIZONTAL POSITION. |
| | |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | |