| 2013-01-04 10:16:46 | RESIDENTIAL (R3) ADDITION FOURTH BUILDING REVIEW |
| | CHECKLIST. |
| | CODE: 2010 FBC. |
| | |
| | 1- SOIL IN THIS AREA IS QUESTIONABLE. PROVIDE SOIL TEST |
| | REPORT AS REQUIRED BY SEC. R401.4 OF 2010 |
| | FBC-RESIDENTIAL. (REPEAT COMMENT. OWNER SAID HE WILL |
| | HAVE THE TEST DONE ON JANUARY). |
| | |
| | 2- ENGINEER REMOVED NOTE REGARDING THE SOIL BEARING |
| | CAPACITY USED FOR THE DESIGN. ENGINEER TO SPECIFY SOIL |
| | BEARING CAPACITY FOR WHICH STRUCTURE WAS DESIGNED FOR. |
| | ENGINEER TO READ SOIL TEST REPORT TO VERIFY IF PROPOSED |
| | FOOTING DESIGN IS ADEQUATE BASED ON THE TYPE AND |
| | BEARING CAPACITY OF THE SOIL. SEC. R301.1 OF 2010 FBC. |
| | (REPEAT COMMENT. NOT ADDRESSED). |
| | |
| | 3- REVISE INFORMATION SUBMITTED FOR ACCORDION SHUTTERS |
| | INSTALLATION. ON SHEET 7 OF 7 OWNER SPECIFIED USING |
| | 1/4" TAPCONS AT 6"O.C. WITH CONNECTION TYPE C1. CLEARLY |
| | SPECIFY SHUTTERS MOUNTING TYPE. WALL TRACK MOUNTING ON |
| | SHEET 4 OF 7 SPECIFIES CONNECTION TYPE C3. AND, THIS |
| | CONNECTION TYPE IS NOT ALLOWED. SPECIFY WHICH MOUNTING |
| | CONDITION USING CONNECTION TYPE C1 IS GOING TO BE USED. |
| | SEC. 107.2.1 CITY AMENDMENTS TO FBC. |
| | |
| | 4- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH |
| | COUNTY BUILDING (2300 N. JOG RD.) TO VERIFY IF IMPACT |
| | FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY OF PAID |
| | RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY IMPACT |
| | FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561)805-6712 |