| Notes |
| Date |
Text |
| 2012-04-10 15:00:14 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. BLOCK SUBSTRATE, 58.6 PSF, REQUIRES 8" ANCHOR | | | SPACING, SEE CHART ON SHEET 11. | | | | | | PLEASE SEE INSTALLATION SHEDULE AND ENGINEERING. ZONE 4 | | | 10SF PRESSURE OF -47.4 WAS CIRCLED, AND ZONE 5 10SF | | | PRESSURE OF -58.6 WAS CIRCLED. FOR DESIGN PRESSURE ON | | | THE INSTALLATION SCHEDULE, +47.4/-58.6 WAS PROPOSED. | | | NOT CLEAR WHAT INTENT WAS; PLEASE FEEL FREE TO CONTACT | | | ME IF YOU NEED ASSISTANCE. | | | | | | | | | |
|