| 2012-05-29 15:53:31 | BUILDING PLAN REVIEW |
| | PERMIT: 12040044 |
| | ADD: 1711 WORTHINGTON BLDG PHASE I BLDG 100 SUITE 108 |
| | BUSINESS |
| | CONT: ONICX LLC |
| | TEL: (813)964-0666 |
| | |
| | 2010 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | MAY 28/2012 |
| | ACTION: DENIED |
| | |
| | 1) THE CONTRACTOR IS TO COME IN AND CHANGE THE PERMIT |
| | APPLICATION UNDER THE HEADING DESCRIPTION OF WORK. THE |
| | PERMIT APPLICATION AND PLANS NEED TO USE THE SAME |
| | NOMENCLATURE THE PLANS INDICATE THIS PORTION OF WORK AS |
| | PHASE I BLDG 100 BUSINESS L/ CHANGE IN OCCUPANCY. |
| | |
| | 2) SHEET A-0.0 COVER SHEET & INDEX; |
| | 2A) COMPLIED. |
| | |
| | 2B) COMPLIED. |
| | |
| | 2C) SEMI-COMPLIED. THE HEADING OF CODE INFORMATION |
| | FBC-B 803.5 INDICATES, CLASS E FOR EXITS & |
| | CORRIDORSCORRECT OCCUPANCY TYPE FOR OFFICES. |
| | |
| | |
| | 2D) PRODUCT APPROVAL ARE LOADED UPSIDE DOWN. |
| | THE COVER SHEET ALSO INDICATES THE USE OF YKK YES40F1 |
| | WINDOW PRODUCT APPROVALS FL 7606.1 PLEASE NOTE THIS |
| | REPORT IS FOR NON- MISSILE RATED GLAZING WHICH WILL |
| | REQUIRE PRODUCT TESTING REPORT FOR STORM PANELS. |
| | |
| | THE OTHER ISSUE WITH THE SUBMITTED FL 7606.1 REPORT |
| | ONLY THE COVER SHEETS WERE UPLOADED, THE ACTUAL |
| | EVALUATION REPORT WITH PRESSURES WAS NOT INCLUDED NOR |
| | WAS THE INSTALATION INSTRUCTIONS THAT TIE TO THE |
| | FLORIDA COVER SHEET. |
| | |
| | PROVIDE STORM PANEL INFORMATION WITH INSTALLATION |
| | SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND |
| | MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC |
| | 1609.1.4. |
| | |
| | FL BLD CODE 2004 SECTION 106.3.3, |
| | 1609.1.4, 1714.5.1 & EXIST BUILD CODE 507.3. |
| | PROCEDURES: 1(B) A COMPLETE INSTALLATION SCHEDULE |
| | SUMMARIZING & IDENTIFYING OPENING SIZES, STORY HEIGHTS, |
| | UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM BAR |
| | REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT |
| | TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT |
| | APPLICATION TO FACILITATE PLAN REVIEW AND PERMIT |
| | ISSUANCE. |
| | |
| | 2E) THE SECOND PRODUCT APPROVAL THE COVER SHEET LISTED |
| | IS FOR EXTERIOR OUTSWING YKK DOOR FL 9967.1 NO REPORT |
| | WAS FOUND UNDER THIS PRODUCT NUMBER. |
| | |
| | 2F) PLEASE CORRECT THE TITLE SHEET FOR THE BUSINESS |
| | OFFICES PERMIT BY REMOVING ALL REFREENCES TO THE |
| | EDUCATIONAL OCCUPANCY, NOT PART OF THE SCOPE OF WORK |
| | UNDER THIS PERMIT. |
| | |
| | 3) SHEET A-1.0: |
| | 3A) PLEASE PROVIDE THE DISTANCE BETWEEN THE TWO |
| | BUILDINGS AND PROVIDE COMPLIANCE WITH FBC-B TABLE 602 |
| | OR ARE THEY CONSIDERED BUILDINGS ON SAME LOT UNDER |
| | FBC-B 503.1.2. |
| | |
| | 3B) COMPLIED. |
| | |
| | 4COMPLIED. |
| | |
| | 5)BUSINESS OCCUPANCY / NOT A CHANGE OF OCCUPANCY , |
| | COMPLIED. |
| | |