2012-04-02 15:51:32****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. GOVERNING CODE CHANGED TO FBC 2010 EFFECTIVE MARCH
 15, 2012. PLEASE REVISE ENGINEERING.
  
 2. PLEASE REVISE ITEM 6 ON ENGINEERING; IT STATES THAT
 FABRIC IS TO BE REMOVED AT 75MPH (90 MPH 3 SECOND
 GUST). THIS IS NOT ACCURATE, 75MPH IS A 3 SECOND GUST,
 NOT SUSTAINED, AND IS NOT THE SAME AS 90MPH. FBC
 3105.4.2.1.
  
  
  
  
  
  
  