2012-04-09 16:12:29BUILDING PLAN REVIEW
 PERMIT: 12030454
 ADD: 319 CLEMATIS ST 1ST/ 2ND FLOOR COMMON AREAS
 CONT: CLAY KOHLMEYER GENERAL CONTRACTING
 TEL: (561)719-3429
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
 1) PLANS INDICATE THEY ARE DESIGNED TO THE 2007/09 FBC,
 AS OF MARCH 15, 2012 PLANS SUBMITTED FOR PERMIT ARE TO
 BE DESIGNED TO THE FAMILY OF 2010 FBCODES.
  
 2) THE COVER SHEET & LIFE SAFETY SHEET INDICATE THIS
 BUILDING TO BE A TYPE II-B CONSTRUCTION. 2007/09 FBC-B
 TABLE 503 TO BE A 10 STORY BUILDING WITH BUSINESS
 OCCUPANCIES THE BUILDING TYPE WOULD BE A MINIMUM OF A
 TYPE IB.
  
 3) THE PLANS ARE DEFICIENT IN INDICATING RATED WALLS,
 STAIRWELLS, FIRE PUMP ROOMS, TENANT SEPERATION WALLS,
 THERE ARE NO CUT SECTION OF WALLS INDICATING LISTED
 ASSEMBLIES AND HOUR OF FIRE RATING FOR FIRE RATED WALLS
 AND OPENING PROTECTIVES. FBC-B 707,708, 709 & TABLE
 715.4.
  
 4) PLEASE PROVIDE COMPLIANCE WITH 2010 FBC-B 713.6
 "FIRE & SMOKE BARRIERS PROTECT ALL OPENINGS".
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved