| Plan Review Notes For Permit 12030269 |
| Permit Number |
12030269 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2012-03-15 11:46:59 | REVISED ASSEMBLY APPROVED AFTER ROBERT BROWN (AND | | | JULIO) PHONE CONVERSATION WITH ANDY SMALL FROM LIFETIME | | | ROOF & CONSTRUCTION INC, TO CLARIFY PROPOSED | | | INSTALLATION. | | | | | | THE REVISED INSTALLATION IS FOR THE NORTHERN SLOPE OF | | | 4:12 PITCHED ROOF. THE PROPOSED INSTALLATION AS | | | DESCRIBED IN THE REVISION FORM IS AS FOLLOWS: | | | "INSTALL 30# ASTM D226 FASTENED TO T/G 3 1/4" ROOF DECK | | | USING 1.25" NAILS & TAGS - INSTALL 4'X4'X2" ISO OVER | | | 30# USING 3" SCREWS & 3" PLATES - INSTALL 30# ASTM D | | | 226 OVER ISO USING 3" SCREWS & 3" PLATES - INSTALL CTD | | | FLINTLASTIC GMS OVER 30# FULLY MOPPED AT A RATE OF | | | 25LBS/SF." THEN THE CONCRETE TILE IS INSTALLED USING |
|