| Notes |
| Date |
Text |
| 2012-03-12 19:16:27 | REVSIED PRODUCT APPROVALS FOR UNDERLAYMENT AND | | | INSULATION. | | | | | | | | | PLEASE SUBMIT ADDITIONAL INFORMATION: | | | | | | COMPATIBILITY OF PRODUCTS - NEITHER NOTICE OF | | | ACCEPTANCE (NOA) LISTS THE OTHER OTHER MANUFACTURER'S | | | PRODUCT AS A COMPONENT PART OF AN ASSEMBLY. PER | | | LIMITATION 8 ON PAGE 6 OF CERTAINTEED CORPORATION NOA# | | | 10-0608.01, AND LIMITATION 2 ON PAGE 3 OF GENFLEX | | | ROOFING SYSTEMS NOA# 08-1117.01, ADDITIONAL | | | DOCUMENTATION IS REQUIRED TO DEMONSTRATE COMPATIBILITY | | | OF THE UNDERLAYMENT AND INSULATION BOARD. SUCH | | | DOCUMENTATION MAY BE IN THE FORM OF A LETTER FROM THE | | | MANUFACTURER, OR AUTHORIZED REPRESENTATIVE, OF EACH | | | PRODUCT STATING THAT THEY HAVE NO OBJECTION TO THE USE | | | OF THEIR PRODUCT WITH THE OTHER MANUFACTURER'S PRODUCT. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | TELEPHONE: (561) 805 6652 ROBERT BROWN | | | E-MAIL: [email protected] |
|