| 2012-03-14 14:13:57 | BUILDING PLAN REVIEW |
| | PERMIT: 12030123 |
| | ADD: 401 S DIXIE HWY |
| | CONT: TBD |
| | TEL: (561)366-8286 |
| | |
| | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | NOTE: SHEET A-1.0 INDICATES AN EXISTING VERTICAL EXIT |
| | STAIR THAT LEADS INTO A LOBBY, NOT TO A EXIT PASSAGE |
| | WAY OR EXIT DISCHARGE. UNDER THE 2007/09 EXISTING |
| | BUILDING CODE SECTION |
| | 703.2.3 THE WORK AREA WOULD NEED TO EXCEED 50% OF THAT |
| | FLOOR AREA TO ENACT THIS SECTION. THAT THE 50% LIMIT |
| | HAS NOT BEEN REACHED, THIS IS ONLY A NOTICE OF A |
| | PRE-EXISTING NON-CODE COMPLIANT AREA OF THE BUILDING. |
| | |
| | 1) THE NEW TENANT WALL THAT SEPERATES THE LOBBY FROM |
| | THE NEW TENANTCY, PLEASE PROVIDE COMPLIANCE WITH |
| | SECTION FBC-B 708.1 TENANT SEPERATION WALLS REQUIRING 1 |
| | HOUR SERARATION FOR THE GLASS WALL SECTION AND OPENING |
| | PROTECTION FOR GLAZED DOORS PER FBC-B T 715.4. |
| | |
| | 2)SHEET A-1.0 INDICATES THE INSTALATION OF NEW EXTERIOR |
| | BI-PARTING DOORS AND OR NEW BI-PATING DOORS WITH SIDE |
| | LIGHTS AND NEW WINDOWS. |
| | FBC-B 1609 COMPONENTS & CLADDING. |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS. BI-PARTING DOORS. |
| | (B) WINDOWS |
| | C) MULLIONS |
| | |
| | 4) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE |
| | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 5) PLEASE PROVIDE DOCUMENTATION FOR CODE COMPLIANCE FOR |
| | THE EXTERIOR BI-PARTING EXTERIOR DOORS FBC-B |
| | 1008.1.3.2. WITH LOSS OF POWER HOW WILL THESE DOORS |
| | STILL FUNCTION AS PART OF THE MEANS OF EGRESS. |
| | |
| | 6) SHEET A-2.0 DETAIL DOOR TYPE B3 THE BIPARTING DOORS |
| | AND TRANSOM ABOVE, WHAT TYPE OF STRUCTURAL MEMBER WILL |
| | BE LOCATED BETWEEN THE BI-PARTING DOORS AND TRANSOM |
| | WINDOWS ABOVE? HOW WILL IT BE ANCHORED INTO THE MAIN |
| | WIND FORCE RESISTING SYSTEM? |
| | |
| | 7) SHEET A-1.0 THE NEW MAILBOX ROOM PLEASE SHOW |
| | COMPLIANCE FOR THE WHEELCHAIR TURNING SPACE PER FBC-B |
| | 11-4.2.3 & FIGURE 3. |
| | |
| | 8) SHEET S-2 GLASS & ALUMINUM FRAME CANOPY DESIGGN, |
| | FABRICATION AND ASSEMBLY SHALL CONFORM TO AAASM 35 AND |
| | SPECIFICATIONS FOR ALUMINUM STRUCTURES. |
| | |
| | 9) SHEET S-2GLAZING IN SLOPED ASSEMBLIES SHALL COMPLY |
| | WITH FBC-B 2405.2 ALLOWABLE GLAZING MATERIALS AND |
| | LIMITATIONS. |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |