| 2012-04-02 16:18:05 | 2007 FBC W/2009 REVISIONS |
| | 140 MPH, EXPOSURE CATEGORY C |
| | FLOOD ZONE B |
| | |
| | DENIED BY BUILDING |
| | |
| | 1) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE |
| | GARAGE TO COTTAGE CONVERSION AS REQUIRED BY 2007 ENERGY |
| | GLITCH AMENDMENTS SECTION 1108.0.8. |
| | |
| | 2) PROVIDE STRUCTURAL DETAILS FOR THE EXTERIOR WALLS |
| | AND THE OPENINGS FOR THE FRENCH DOORS. FBC R601.2 |
| | |
| | 3) SPECIFY THE WIND DESIGN DATA AND THE REQUIRED DESIGN |
| | PRESSURES FOR THE NEW EXTERIOR DOORS ON THE PLANS. FBC |
| | R301.2.1 |
| | |
| | 4) SPECIFY THE HEIGHT OF THE FRENCH DOORS ON THE PLANS. |
| | FBC R301.2.1 |
| | |
| | 5) SUBMIT TWO CURRENT PRODUCT APPROVALS FOR THE |
| | OUT-SWING FRENCH DOORS AS REQUIRED BY DCA RULE 9N-3. |
| | THE ONES THAT WERE SUBMITTED (09-0316.06) ARE EXPIRED. |
| | |
| | 6) IN ORDER TO VERIFY WIND REQUIREMENTS OF FBC |
| | R301.2.1, PLEASE SUBMIT TWO COPIES OF AN INSTALLATION |
| | SCHEDULE FOR THE STORM PANELS. SPECIFY THE OPENING |
| | PRESSURES, THE CONNECTION/MOUNT TYPE, THE EDGE |
| | DISTANCE, GLASS SEPARATION DISTANCE, SPAN, FASTENER |
| | TYPE AND SPACING. |
| | |
| | 7) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 8) PLEASE IDENTIFY THE DRAWINGS BY INDICATING THE |
| | PROJECT AND ADDRESS ON THE PLANS. |
| | |