Plan Review Notes
Plan Review Notes For Permit 12020503
Permit Number 12020503
Review Stop B
Sequence Number 1
Notes
Date Text
2012-03-12 11:51:49BUILDING PLAN REVIEW
 PERMIT: 12020503
 ADD: 515 N FLAGLER P-100
 CONT: CUTTING EDGE BUILDING
 TEL: (561)282-8265
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) LIFE SAFETY SHEET LS-1:
 1A) PLANS FAIL TO IDENTIFY THE TENANT SEPERATION WALL
 RATING.2007/09 FBC-B 106.3.5.1.1(4) / FBC-B 708.1
 TENANT SEPERATION WALLS, 1 HOUR RATING.
  
 1B) THE CODE RESEARCH INDICATES THIS PLANS TO BE A
 BUSINESS OCCUPANCY, PLEASE SEE 303.1 A-3 GYMNASIUM
 WITHOUT SPECTATOR SEATING, IT APPEARS THIS MAY BE A
 CHANGE OF OCCUPANCY WHICH WOULD BE REVIEWED UNDER THE
 EXISTING BUILDING CODE 901.3.1 SECTION 912 OF THE
 EXISTING BUILDING CODE WOULD APPLY.
  
 1C) WITH THE A-3 OCCUPANCY THE OCCUPANT LOAD WILL
 CHANGE PLEASE SEE FBC-B TABLE 1004.1.1 EXERCISE ROOMS/
 GYMASIUMS WITH EQUIPMENT 50 GROSS AND ROOMS WITHOUT
 EQUIPMENT 15 GROSS PLEASE MAKE THE REQUIRED OCCUPANT
 LOAD ADJUSTMENTS.
  
 1D) WITHIN THE TENANT SPACE IT APPEARS THAT A VERTICAL
 EXIT (EXIT STAIRS) ARE LOCATED, IS THIS A 1 HOUR RATING
 OR TWO HOUR RATING? IS THIS TENANT SPACE A NEWLY
 CREATED SPACE?
 DO WE STILL HAVE A CODE COMPLIANT EXITING FOR THE FIRST
 FLOOR SINCE THE OCCUPANTS ON THE REMAINDER OF THE FIST
 FLOOR MAY NOT BE ABLE TO USE THIS STAIR?
  
 2) SHEET A-2.0 DETAILS 20 & 21 BOTH INDICATE THE
 ACCESSIBLE WATER CLOSET AT 1'-5" FROM THE SIDE WALL.
 2007/ 09 FBC-B 11-4.16.2 WATER CLOSETS SHALL COMPLY
 WITH FIGURE 11-28 WHICH SHOWS THE WATER CLOSET CENTERED
 AT 18 INCHES FROM THE SIDE WALL.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]


Account Summary | Usage Policy | Privacy Policy