| 2012-03-27 11:43:28 | BUILDING PLAN REVIEW |
| | PERMIT: 12020282 |
| | ADD: 2275 PALM BEACH LAKES BLVD |
| | CONT: CUTTING EDGE BUILDING SYSTEMS, INC |
| | TEL: (561)282-8265 |
| | |
| | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | |
| | BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | THE THREE ISSUES WERE RED LINED AS FOLLOWS: |
| | SHEETS LS-1.0 & A-1.0 |
| | 1) CORRIDOR DOOR E1 INFRONT OF EXAM ROOM # 7 TO BE |
| | REVERSED SWING IN THE DIRECTION OF EGRESS TRAVEL SEE |
| | 2007/09 FBC-B 1008.1.2 OR FL INFORMAL INTERPRETATION |
| | 4245. |
| | |
| | 2) CORRIDOR DOOR C1 DIRECTLY OPPOSITE EXAM ROOM # 5 TO |
| | BE RESERVED SWING TO ALLOW DOOR TO NOT BLOCK EGRESS TO |
| | ROOM 1030 AND ALLOW DOOR TO LAY FLAT AGAINST THE |
| | CORRIDOR WALL PER |
| | 2007/09 FBC-B 1005.2 SEE DOOR ENCROACHMENT. |
| | |
| | 3) CORRIDOR DOOR SEPERATING CORRIDOR W1 & W2 WAS |
| | REVERSED AS REQUIRED BY 2007/09 FBC-B 1008.1.2 THIS |
| | CREATES A SECONDARY PROBLEM WITH 2007/09 FBC-B 11-4. |
| | 13.6 THE REQUIRED 18 INCHES LATCH SIDE OF DOOR, |
| | CONTRACTOR SPOKE WWITH OWNER, BIFOLD DOORS TO BE |
| | REMOVED TO SOLVE THIS CODE ISSUE. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |