| Date |
Text |
| 2012-03-26 14:00:37 | BUILDING PLAN REVIEW |
| | PERMIT: 12020230 |
| | ADD: 420 OKEECHOBEE BLVD |
| | CONT: DEALERSHIP SOLUTIONS |
| | TEL: (727)894-2182 |
| | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | BUILDING PROVISO: |
| | WHEN THE WIND DESIGN CRITERIA IS CORRECT & NO APPROVALS |
| | ARE SUBMITTED THEN A PERMIT CAN BE ISSUED WITHOUT |
| | PRODUCT APPROVALS, THE PRODUCT APPROVALS CONSIDERED |
| | COMPONENTS & CLADDING WILL BE CONSIDERED A REVISION |
| | WITH SEPARATE REVIEW AND ASSOCIATED FEES. |
| | 1) SHEET A000 PRODUCT APPROVAL INFORMATION |
| | |
| | THE SUMMARY OF THE PRODUCT APPROVALS DOES NOT HELP IN |
| | CODE COMPLIANCE REVIEW OR IN THE FIELD FOR INSTALLATION |
| | WHEN THE FULL PRODUCT APPROVALS ARE NOT SUBMITTED. WITH |
| | THE FULL PRODUCT REPORT PLEASE CIRCLE WHICH SUB-SYSTEMS |
| | ARE TO BE INSTALLED. MANY REPORTS PROVIDE OPTIONS FOR |
| | TYPE OF GLAZING, EACH HAVING THEIR OWN TEST PRESSURES. |
| | PLEASE NOTE THE ROOFING REPORT FL 3915 COULD NOT BE |
| | LOCATED ON LINE. DEPENDING ON THE ROOFING REPORT THERE |
| | MAY BE SUB-SYSTEMS AND VARYING PRESSURES WHICH MAY |
| | REQUIRE ENHANCED FASTENING IN ZONES 2 & 3. |
| | |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS. |
| | (B) WINDOWS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| | LOUVERS, EFIS SYSTEMS, |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES |
| | |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |