| Plan Review Notes For Permit 12020230 |
| Permit Number |
12020230 |
|
| Review Stop |
FIRE |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-02-16 12:19:01 | 420 OKEECHOBEE BOULEVARD | | | PERMIT #12020230 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ALL DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS | | | OF NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | | REMOVED FROM THE SITE DAILY. | | | | | | IN ADDITION TO THE FLORIDA BUILDING CODE, THE DESIGN | | | SHALL CONFORM TO THE 2010 EDITION OF THE FLORIDA FIRE | | | PREVENTION CODE WHICH CONTAINS THE FLORIDA 2009 EDITION | | | OF NFPA 1 AND NFPA 101. | | | | | | PROVIDE BUILDING ADDRESS VISIBLE FROM THE STREET. | | | NUMBERS SHALL BE ATTACHED TO THE BUILDING AND BE AT | | | LEAST SIX-INCHES IN HEIGHT WITH 1-INCH STROKE AND SHALL | | | CONTRAST THE BACKGROUND. | | | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | THUMB-TURN LOCK TO BE EQUIPPED WITH A LOCK/UNLOCK | | | INDICATOR. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|