2012-01-30 10:16:58 
 BUILDING PROVISO:
  
 2007/09 FBC-B
 1026.2 MINIMUM SIZE. EMERGENCY ESCAPE AND RESCUE
 OPENINGS SHALL
 HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET
 (0.53 M2).
  
 EXCEPTION: THE MINIMUM NET CLEAR OPENING FOR EMERGENCY
 ESCAPE AND
 RESCUE GRADE-FLOOR OPENINGS SHALL BE 5 SQUARE FEET
 (0.46 M2).
  
 1026.2.1 MINIMUM DIMENSIONS. THE MINIMUM NET CLEAR
 OPENING HEIGHT
 DIMENSION SHALL BE 24 INCHES (610 MM). THE MINIMUM NET
 CLEAR OPENING
 WIDTH DIMENSION SHALL BE 20 INCHES (508 MM). THE NET
 CLEAR OPENING
 DIMENSIONS SHALL BE THE RESULT OF NORMAL OPERATION OF
 THE OPENING.
  
  