Plan Review Notes
Plan Review Notes For Permit 12010509
Permit Number 12010509
Review Stop B
Sequence Number 1
Notes
Date Text
2012-01-25 14:00:29BUILDING PLAN REVIEW
 PERMIT: 12010509
 ADD: 805 20TH ST
 CONT: VICTORY ENGINEERING & GENERAL CONTRACTORS
 TEL: (305)244-5424
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) ADDITIONAL INFORMATION REQUIRED.106.1.2.
 NO FLOOR PLAN WAS SUBMITTED INDICATING WHICH WINDOWS
 WERE REPLACED, A FLOOR PLAN IS REQUIRED AS PART OF A
 MINIMUM PLAN REVIEW. 2007/09 FBC-B 106.3.5.4(5).
  
 1A) PLEASE INDICATE ROOM TYPES, IF ONE STORY OR TWO
 STORY.
 PLEASE NOTE THE REPLACEMENT WINDOW SIZE THAT WAS
 INSTALLED. PLEASE NOTE WHICH ROOMS ARE SLEEPING ROOMS
 THAT REQUIRE EGRESS WINDOWS. FBC-B 1026.2.
 5'-0" SQUARE FEET OF CLEAR VENT AREA FOR 1ST FLOOR
 WINDOWS.
 5.7 SQ FT FOR EGRESS WINDOWS FOR 2ND FLOOR.
  
 1B) PLEASE INDICATE WHAT PERCENTAGE OF GLAZED OPENINGS
 WERE REPLACED, 2007/09 EXST BLDG CODE 606.4 REQUIRES
 EITHER LARGE MISSILE IMPACT RATED WINDOWS OR STORM
 SHUTTERS. EXCEPTION IF 25% OR LESS OF THE GLAZED AREA
 OF WINDOWS AND DOORS WERE REPLACED THEN STORM SHUTTERS
 ARE NOT REQUIRED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  