| 2012-01-25 14:00:29 | BUILDING PLAN REVIEW |
| | PERMIT: 12010509 |
| | ADD: 805 20TH ST |
| | CONT: VICTORY ENGINEERING & GENERAL CONTRACTORS |
| | TEL: (305)244-5424 |
| | |
| | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) ADDITIONAL INFORMATION REQUIRED.106.1.2. |
| | NO FLOOR PLAN WAS SUBMITTED INDICATING WHICH WINDOWS |
| | WERE REPLACED, A FLOOR PLAN IS REQUIRED AS PART OF A |
| | MINIMUM PLAN REVIEW. 2007/09 FBC-B 106.3.5.4(5). |
| | |
| | 1A) PLEASE INDICATE ROOM TYPES, IF ONE STORY OR TWO |
| | STORY. |
| | PLEASE NOTE THE REPLACEMENT WINDOW SIZE THAT WAS |
| | INSTALLED. PLEASE NOTE WHICH ROOMS ARE SLEEPING ROOMS |
| | THAT REQUIRE EGRESS WINDOWS. FBC-B 1026.2. |
| | 5'-0" SQUARE FEET OF CLEAR VENT AREA FOR 1ST FLOOR |
| | WINDOWS. |
| | 5.7 SQ FT FOR EGRESS WINDOWS FOR 2ND FLOOR. |
| | |
| | 1B) PLEASE INDICATE WHAT PERCENTAGE OF GLAZED OPENINGS |
| | WERE REPLACED, 2007/09 EXST BLDG CODE 606.4 REQUIRES |
| | EITHER LARGE MISSILE IMPACT RATED WINDOWS OR STORM |
| | SHUTTERS. EXCEPTION IF 25% OR LESS OF THE GLAZED AREA |
| | OF WINDOWS AND DOORS WERE REPLACED THEN STORM SHUTTERS |
| | ARE NOT REQUIRED. |
| | |