| 2012-02-15 12:32:15 | R06 |
| 2012-02-08 10:57:50 | RESIDENTIAL (R3) BUILDING REVIEW COMMENTS. |
| | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. |
| | |
| | 1- PLEASE PROVIDE PRODUCT APPROVALS (2 COPIES) AS |
| | REQUIRED BY DCA RULE 9N-3 FOR: |
| | A) CLAY ROOF TILE AS SPECIFIED ON PLANS. AND, CLEARLY |
| | SPECIFY INSTALLATION METHOD FOAM OR SCREWS. |
| | |
| | B) FOAM IF USING FOAM FOR CLAY ROOF TILE INSTALLATION. |
| | SEE TILE PRODUCT APPROVAL FOR LISTED FOAM. |
| | |
| | C) WINDOW MULLIONS AS SHOWN ON PLANS. AND, CLEARLY |
| | SPECIFY ON PRODUCT APPROVAL MULLION SIZE AND ANCHORING |
| | |
| | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS PRIOR |
| | TO SUBMITTAL TO THIS OFFICE AS REQUIRED BY SEC. 106.3.3 |
| | CITY AMENDMENTS TO FBC. |
| | ***NOTE: SOME PRODUCT APPROVALS SUBMITTED ARE NOT THE |
| | SAME AS THE ONES THAT WERE SPECIFIED ON THE DOOR/WINDOW |
| | SCHEDULES. REVISE AS REQUIRED TO MATCH. |
| | |
| | 3- REVISE ALL DETAILS AND WALL SECTIONS TO SHOW THE |
| | R-VALUE FOR THE CEILINGS AND WALLS INSULATION AS |
| | SPECIFIED ON THE ENERGY CALCULATIONS. |
| | |
| | 4- SPECIFY ATTIC ACCESS SIZE AND LOCATION FOR NEW ATTIC |
| | AREA IN THE FAMILY ROOM AS REQUIRED BY SEC. R807. |
| | |
| | 5- SHEET A-1: A) LEGAL DESCRIPTION SHOWN ON THE SITE |
| | PLAN IS FOR A PROPERTY IN MIAMI-DADE. REVISE. |
| | |
| | B) DEMOLITION NOTES SPECIFY FBC 2004. REVISE TO CURRENT |
| | CODE. |
| | |
| | 6- SHEET A-2: REVISE GENERAL CONSTRUCTION NOTE #2. MIN. |
| | WIDTH OF ATTIC ACCESS IS 22" NOT 20". SEC. R807. |
| | |
| | 7- FENCES REQUIRE SEPARATE PERMIT. PROVIDE COMPLETE |
| | INFORMATION UNDER A SEPARATE PERMIT. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561)805-6712 |