| Plan Review Notes For Permit 12010305 |
| Permit Number |
12010305 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-01-24 10:55:01 | BUILDING PROVISO: | | | GYPSUM BOARD IN SHOWERS | | | 2007/09 FBC-B 2509.2 BASE FOR TILE. CEMENT, | | | FIBER-CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE | | | WITH ASTM C 1178, C 1288 OR C 1325 AND INSTALLED IN | | | ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS SHALL BE | | | USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS | | | AND WALL AND CEILING PANELS IN SHOWER AREAS. | | | WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A | | | BASE FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN | | | INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840 AND | | | MANUFACTURER RECOMMENDATIONS. REGULAR GYPSUM WALLBOARD | | | IS PERMITTED UNDER TILE OR WALL PANELS IN OTHER WALL | | | AND CEILING AREAS WHEN INSTALLED IN ACCORDANCE WITH | | | GA-216 OR | | | ASTM C 840. | | | |
|