| Plan Review Notes For Permit 12010161 |
| Permit Number |
12010161 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2012-01-10 09:15:14 | RE-ROOF BUILDING REVIEW COMMENTS. | | | 2007 FBC WITH 2009 REVISIONS. | | | | | | 1-THE WIND SPEED ADOPTED FOR THE CITY OF WEST PALM | | | BEACH IS 140MPH. SEC. 117 CITY AMENDMENTS TO FBC. | | | ENGINEER CALCULATIONS USES 135 MPH WIND SPEED. REVISE | | | CALCULATIONS AS REQUIRED. | | | | | | 2- ENGINEER CALCULATIONS SPECIFIED ROOF PRODUCT | | | APPROVAL SYSTEM S-28 WITH DESIGN PRESSURES OF -52.5 PSF | | | ON PAGE 14 OF FLORIDA PRODUCT APPROVAL FL5293-R3. THIS | | | SYSTEM IS NO SHOWN ON PAGE 14. REVISE/CLARIFY AS | | | REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|