Plan Review Notes
Plan Review Notes For Permit 12010011
Permit Number 12010011
Review Stop B
Sequence Number 1
Notes
Date Text
2012-01-10 15:30:00BUILDING PLAN REVIEW
 PERMIT:12010011
 ADD: 535 E LAKEWOOD RD
 CONT: NOWAK CONSTRUCTION
 TEL: (561)779-9577
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) THE CONTRACTOR OF RECORD IF DOING THEIR OWN DESIGN
 (DRAFTING) ARE TO TAKE OWNERSHIP OF THE PLANS PRINT
 THEIR NAME, SIGN THEIR NAME AND PROVIDE THEIR LICENSE
 NUMBER ON THE PLANS BEFORE SUBMITTAL TO THE BUILDING
 DEPARTMENT.
  
 2) 2007/09 FBC-B 106.3.5 MINIMUM PLAN REVIEW CRITERIA
 FOR BUILDINGS. THE EXAMINATION OF THE DOCUMENTS BY THE
 BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM
 CRITERIA AND DOCUMENTS:
  
 A) 106.3.5 (3)MINIMUM BUILDING TYPE
  
 B) BUILDING SPRINKLERED OR NON-SPRINKLERED
  
 C) IT APPEARS THERE ARE EITHER SEPERATE TENANTS OR
 OCCUPANCY SEPERATION ISSUES NOT INDICATED ON THE PLANS
 (TABLE 508.3.3)/ 708.1. SEPERATED USE OR NON SEPERATED
 508.3.1.3 OR 508.3.2.
  
 106.3.5(2) OCCUPANCY GROUP AND SPECIAL OCCUPANCY
 REQUIREMENTS SHALL BE DETERMINED. THE PBC PROPERTY
 APPRAISERS OFFICE INDICATES THE FOLLOWING SQ FT AREAS:
 1590 S F OFFICE
 1054 S F GARAGE
 4760 S F WAREHOUSE
  
 D) 106.3.5 (6) LIFE SAFETY OCCUPANT LOADS/ EGRESS
 CAPACITY
  
 E) CHANGE IN CEILING/ ROOF ASSEMBLIES?
  
 F) PLANS FAIL TO PROVIDE DETAIL OF 2X4 SPACING, IF THEY
 GO TO A DROPPED CEILING OR TO THE ROOF DECK ABOVE?
  
 G) PLANS FAIL TO PROVIDE DETAILS FOR ACCESSIBILITY TO
 RESTROOMS AND BREAK ROOM AREAS?PLEASE REVIEW 2007/09
 FBC-B CHAPTER 11-4.1.6(2)(A) 20 % DISPROPORTIONATE
 COST.
  
 3) PLEASE REVIEW 2007/09 EXISTING BUILDING CODE CHAPTER
 7 FOR LEVEL 2 ALTERATIONS:
  
 3A) 704.5 EGRESS DOORS.
  
 3B) 706.1. ACCESSIBILITY CHAPTER 11 OF THE FBC-B.
  
 3C) POSSIBLY: 711.1 MINIMUM REQUIREMENTS ENERGY CODE.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  