2012-01-18 14:34:43REVISION, BUILDING REVIEW COMMENTS.
  
 1- PRODUCT APPROVALS SUBMITTED FOR SINGLE HUNG WINDOWS,
 FIXED WINDOWS AND HORIZONTAL SLIDER WINDOWS DON'T MEET
 THE DESIGN PRESSURES CALCULATED BY THE ENGINEER OF
 RECORD. NEED TO PROVIDE PRODUCT APPROVALS THAT MEET THE
 CALCULATED DESIGN PRESSURES REQUIRED BY SEC. R301.2.4.3
 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 2- DRAWINGS SUBMITTED FOR FIXED WINDOW ARE FOR
 NON-IMPACT WINDOWS. NEED TO PROVIDE IMPACT WINDOWS OR
 OPENING PROTECTION AS REQUIRED BY SEC. R301.2.1.2.
  
 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS PRIOR
 TO SUBMITTAL TO THIS OFFICE. SEC. 106.3.3 CITY
 AMENDMENTS TO FBC.
  