| Notes |
| Date |
Text |
| 2012-01-06 07:47:24 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) THE PLANS ON SHEET 1 ARE SPECIFIED AS DESIGNED FOR | | | EXPOSURE CATEGORY B AND PER FBC R301.2.1.4.3, THE | | | STRUCTURE IS LOCATED IN EXPOSURE C. PLEASE CORRECT. | | | | | | 2) THE SPAN SCHEDULES ON SHEET 5 ARE BASED ON EXPOSURE | | | B. SUBMIT SCHEDULES BASED ON EXPOSURE C. FBC | | | R301.2.1.4.3 | | | | | | 3) THE BEAM SPAN SCHEDULES ON SHEET 5 ARE FOR MANSARD | | | OR FLAT ROOFS. THE PLAN SUBMITTED IS FOR A GABLE ROOF. | | | SUBMIT THE APPROPRIATE SCHEDULE. CITY AMENDMENTS | | | 106.1.1 | | | | | | 4) PLEASE PROVIDE A RESPONSE LETTER INDICTING HOW THE | | | REVIEW COMMENTS HAVE BEEN ADDRESSED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|