| 2011-12-01 12:15:05 | RE-ROOF BUILDING REVIEW COMMENTS. | | | 2007 FBC WITH 2009 REVISIONS. | | | | | | 1- MRI SECTION A: PLEASE PROVIDE SIGNED AND SEALED RAS | | | 117 CALCULATIONS (2 COPIES) AS REQUIRED BY GENERAL | | | LIMITATION #7 ON LAST PAGE OF NOA 10-1230.07 SUBMITTED. | | | NEED NAIL ENHANCING TO MEET THE DESIGN PRESSURES OF | | | SEC. 1609 FBC. | | | | | | 2- MRI BUILDING SECTION C: PLEASE PROVIDE SIGNED AND | | | SEALED RAS 117 CALCULATIONS (2 COPIES) AS REQUIRED BY | | | GENERAL LIMITATION #7 ON LAST PAGE OF NOA 10-0719.02 | | | SUBMITTED. NEED NAIL ENHANCING TO MEET THE DESIGN | | | PRESSURES OF SEC. 1609 FBC. | | | | | | 3- PLEASE PROVIDE 2 COPIES OF TAS 105 AND TAS 126 | | | ENGINEERING TESTING. ONLY ONE COPY WAS SUBMITTED. BOTH | | | COPIES TO HAVE ENGINEER'S ORIGINAL SEAL AND SIGNATURE. | | | | | | 4- PLEASE PROVIDE 2 COPIES OF ALL PRODUCT APPROVALS. | | | ONLY 1 WAS SUBMITTED. | | | | | | 5- FOR YOUR INFORMATION: A) ANY RETROFIT ROOF DRAINS | | | REQUIRE PLUMBING REVIEW. | | | B) ANY ROOF EQUIPMENT REMOVAL/RELOCATION REQUIRES | | | SEPARATE PERMIT. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|