| 2011-11-29 16:21:24 | PLEASE RESPOND TO COMMENTS IN WRITING: | | | | | | #1 PROVIDE ANGLE OF EXISTING AND PROPOSED PARKING. | | | | | | #2 PROVIDE BETTER STRIPING TO GUIDE TRAFFIC OUT INTO | | | OKEECHOBEE BLVD. | | | DRIVEWAY IS WIDE ENOUGH TO CAUSE A CONFLICT WHEN | | | VEHICLES PULL OUT UNTO OKEECHOBEE BLVD. | | | | | | #3 PROVIDE "LEFT TURN ONLY" SIGN FOR VEHICLES CUTTING | | | THRU ONEWAY LOOP TO RE-ENTER SITE. | | | STOP SIGN AND STOP BAR WOULD ALSO APPLY. | | | | | | #4 PROVIDE STOP BAR AND STOP SIGN TO AVOID VEHICLES | | | ACCESSING SECONDARY DRIVE THRU AND RE-INTEGRATING UNTO | | | MAIN DRIVE-THRU. | | | | | | #5 KITCHEN SERVICE ACCESS RAMP IS BEING CALLED ADA | | | RAMP. IF IT IS NOT USED FOR GENERAL PUBLIC ADA THEN IT | | | SHOULD NOT DE DESIGNATED AS ADA ON PLANS. | | | | | | #6 I HAVE INCLUDED A SKETCH GENERATED DURING MARK-UPS | | | WITH SOME IDEAS OR SUGGESTIONS (SENT VIA E-MAIL | | | 11/29/2011) | | | | | | #7 ONCE PLAN IS REVISED WITH THE CORRECT PARKING | | | FOOTPRINT AND ISLANDS PLEASE REVISE THE PERVIOUS AND | | | IMPERVIOUS AREAS. | | | | | | MANUEL JULIAN GONZALEZ | | | CSD ENGINEERING REVIEW | | | 401 CLEMATIS STREET, | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|