| Plan Review Notes For Permit 11110177 |
| Permit Number |
11110177 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2011-12-28 08:36:50 | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | 1) VIP LOUNGE | | | 2007/09 FBC-B 1008.1.2 DOOR SWING | | | DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL | | | WHERE SERVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS OR | | | A GROUP H OCCUPANCY. | | | | | | 2) STORAGE ROOM WALLS ARE SHOWN AS TYPICAL WALL TO THE | | | CEILING: | | | 2007/09 FBC-B 508.2.2.1. CONSTRUCTION. | | | | | | WHERE TABLE 508.2 PERMITS AN AUTOMATIC | | | FIRE-EXTINGUISHING SYSTEM WITHOUT A FIRE BARRIER, THE | | | INCIDENTAL USE AREA SHALL BE SEPARATED FROM THE | | | REMAINDER OF THE BUILDING BY CONSTRUCTION CAPABLE OF | | | RESISTING THE PASSAGE OF SMOKE. THE PARTITIONS SHALL | | | EXTEND FROM THE FLOOR TO THE UNDERSIDE OF THE | | | FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY OR | | | FIRE-RESISTANCE-RATED ROOF/CEILING ASSEMBLY ABOVE OR TO | | | THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, OR SUB | | | DECK ABOVE. | | | | | | |
|