| Plan Review Notes For Permit 11100459 |
| Permit Number |
11100459 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2011-10-24 09:32:42 | 2007 FBC W/2009 REVISIONS | | | | | | REVISION DENIED | | | | | | 1) WALLS SEPARATING INDIVIDUAL TENANT SPACES ARE | | | REQUIRED TO BE FIRE PARTITIONS BY FBC 708.1(7). FBC | | | 708.3 | | | REQUIRES FIRE PARTITIONS TO HAVE A FIRE RESISTIVE | | | RATING OF NOT LESS ONE HOUR AND FBC 708.4 REQUIRES FIRE | | | PARTITIONS TO EXTEND FROM THE FLOOR BELOW TO THE | | | UNDERSIDE OF THE ROOF SHEATHING AND BE ATTACHED | | | SECURELY ATTACHED THERETO. THE DESIGN DRAWING THAT WAS | | | SUBMITTED IS NOT A VERTICAL FIRE RATED WALL ASSEMBLY. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|